{"product_id":"anesthesia-machine-wato-ex-20","title":"Anesthesia Machine WATO EX-20 Mindray","description":"\u003ch3 dir=\"ltr\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003eAnesthesia Machine - WATO EX-20 - Mindray \u003c\/h3\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 1375 mm (H) × 715 mm wide without breathing system \/ 880 mm with breathing system × 620 mm (D)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Under 120 kg (excluding vaporizers and cylinders)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eTop shelf:\u003c\/strong\u003e 30 kg weight limit, 550 × 265 mm\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eWork surface:\u003c\/strong\u003e 820 mm (H) × 500 mm (W) × 310 mm (D)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eStorage drawer (internal):\u003c\/strong\u003e 135 × 390 × 315 mm\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBag arm:\u003c\/strong\u003e 1030 mm height, 320 mm length, ISO 22mm OD\/15mm ID connection\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCasters:\u003c\/strong\u003e 125 mm diameter, all four with brakes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eDisplay\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e7.0\" color active matrix TFT screen, 800 × 480 resolution, non-adjustable brightness\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eDisplays all settings\/alarms: breath rate, I:E ratio, tidal volume, minute volume, PEEP, MEAN, PEAK, PLAT, O₂ concentration\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWaveforms: P-T, F-T, V-T\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eVentilation Modes\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eManual \/ Spontaneous \/ Bypass\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eVolume Control Ventilation (VCV) with PLV function\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePressure Mode Ventilation (P-mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eVentilation Parameter Ranges\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\" class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eRange\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTidal volume\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e40–1500 mL (Volume) \/ 5–1500 mL (Pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePinsp\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5–60 cmH₂O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePlimit\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10–100 cmH₂O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRate\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4–100 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eI:E\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4:1 to 1:8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInspiratory pause\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOFF, 5–60%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePEEP\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOFF, 4–30 cmH₂O (electronically controlled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDriving pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e280–600 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePeak gas flow\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e120 L\/min + Fresh Gas Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eMonitoring Parameters\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eMinute volume (0–100 L\/min), tidal volume (0–2500 mL), FiO₂ (18–100%), peak\/mean\/plateau pressure (-20 to 120 cmH₂O), PEEP (0–70 cmH₂O), sweep speed (12.5 or 6.25 mm\/s)\u003c\/p\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eAccuracy\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eVolume delivery: ±15 mL (\u0026lt;75 mL) or ±20 mL\/±10% (≥75 mL)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePressure monitoring: ±3.0 cmH₂O or ±8% of reading\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePEEP monitoring: ±2.0 cmH₂O or ±10% (up to 30 cmH₂O)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eTrend Data\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e24-hour trend charts (5-second resolution) and trend tables (30s–4min resolution) for TVe, Ppeak, MV, Pplat, PEEP, Pmean, Rate, and optional FiO₂\u003c\/p\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eAlarms\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eConfigurable low\/high limits for tidal volume, minute volume, inspired O₂, airway pressure; 20-second apnea alarm\u003c\/p\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eVaporizers\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eCompatible with Mindray V60 or Penlon Sigma Delta\/Alpha vaporizers; supports Desflurane, Halothane, Enflurane, Isoflurane, Sevoflurane; dual-position Selectatec®\/Plug-in® mounting with interlock\u003c\/p\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eElectrical \u0026amp; Battery\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePower input: 100–240 Vac, 50\/60 Hz\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBuilt-in Li-ion battery, 11.1 VDC, 4400 mAh (1–2 units)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eBackup time: 90 min (1 battery) \/ 150 min (2 batteries)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eRJ45 network interface for software upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003ePneumatic System\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eGas supply: pipeline 0.28–0.6 MPa, PISS cylinder inputs (max. 2)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eO₂ flush: 25–75 L\/min\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eMechanical flowmeters for O₂, Air, N₂O with dual-range flow tubes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eO₂–N₂O link system (mechanical, min. 25% O₂ concentration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eBreathing Circuit\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eVolume: 2600 mL (automatic) \/ 1800 mL (manual)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCO₂ absorber capacity: ~1500 mL\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eInspiration\/expiration resistance: \u0026lt; 6.0 cmH₂O @ 60 L\/min\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eAPL valve range: 1–75 cmH₂O\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eWater trap: 6 mL, removable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eScavenging System (AGSS)\u003c\/h4\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eActive (high\/low flow) or passive disposal, compliant with ISO 80601-2-13; pump rate 25–105 L\/min depending on mode\u003c\/p\u003e\n\u003ch4 dir=\"ltr\" class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eEnvironmental Operating Range\u003c\/h4\u003e\n\u003cul dir=\"ltr\" class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eTemperature: 10–40°C\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eHumidity: 15–95% (non-condensing)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePressure: 70–106 kPa\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mindray","offers":[{"title":"Default Title","offer_id":44053020901454,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/9130\/9902\/files\/20200302160741_8997-1.jpg?v=1784747430","url":"https:\/\/profmedix.com\/products\/anesthesia-machine-wato-ex-20","provider":"Profmedix","version":"1.0","type":"link"}